Firefighter Training Drill: The Triangle Cut

Peaked Roof Ventilation Operations with a Saw

By Danny Troxell
Captain, Washington, D.C. Fire Department
Instructor, Traditions Training LLC.

Ventilation operations on尖顶are usually only necessary when fire is in (or thought to be in) theattic. They are also sometimes necessary if fire is located in the basement and/or walls of a balloon-frame structure. In this case, venting the roof will relieve the pressure from the heat and smoke that is building up in the stud bays and slow the spread of the fire. In either case, operations on peaked roofs that have a pitch of 5-12 or over are often very difficult and dangerous to conduct. The utilization of a roof ladder is a must, and it is extremely important that the member making the cuts stays on the roof ladder as much as possible. This can be quite tricky when trying to make the standard 4 ft. x 4 ft. or 4 ft. x 8 ft. opening. In light of these facts, the “Triangle Cut” is a faster and safer method that can be utilized to make a substantial opening on a peaked roof.

The step-by-step procedures for this method are outlined in thisdrill. Hopefully it will provide your members with yet another tool in the toolbox that can be used when this operation is required on the fireground.

Download this firefightertrainingdrill as a PDFHERE.

MORE DANNY TROXELL

MORE TRADITIONS TRAINING

Traditions Training:http://traditionstraining.com/

No posts to display